air handling unit ahu

North American School Systems Course & Event Calendar SmartCool™ 11kW – 233kW SmartCool™ Inverter Compressor 5kW – 83kW EasiCool™ 6kW – 64kW Ecotel™ FreeCool 5kW – 15kW Ecotel™ DX 5kW – 15kW OnRak™ 3kW – 35kW InRak™ 10kW – 67kW Echo™ up to 20kW AireTile™ Up to 1.2m³/s DeltaChill™ & DeltaChill™ FreeCool 110kW – 1080kW TurboChill™ & TurboChill™ FreeCool 200kW – 1830kW TurboChill™ Water Cooled 150kW - 1576kW OptiChill™ & OptiChill™ FreeCool 500kW – 1365kW LogiCool™ FreeCool 20kW – 40kW Ultima™ Compact & Ultima™ Compact FreeCool 30kW – 450kW Ultima™ Remote Air Cooled 75kW – 450kW Ultima™ Water Cooled 75kW – 450kW Chilled Water Cassette 2kW – 11kW BluCube™ 10kW – 48kW Air Cooled Condensers & Dry Coolers 12kW - 174kW Condensing Units (CU) 3kW – 80kW Ultima™ Compact Condensing Unit 30kW – 450kW

AireFlow™ 100kW – 440kW Contact an Airedale Account Manager View a Product Guide (online version) Download a Product Guide (.pdf) See inside our production facility Showing results 1 - 1 of 1 Designed for roof and wall connections and requires minimal mechanical cooling, delivering huge free-cooling potential to significantly reduce operational costs. People Who Viewed This Also Viewed... Air Handling Unit range Designed to perform, our highly versatile range of Air Handling Units (AHUs) are configured for wall or roof mounted applications. Requiring minimal mechanical cooling and offer huge free-cooling potential - maximising efficiency and minimising operational costs. Multi-purpose air handling and conditioning units The design solutions, drawing on the company’s knowledge and experience, fully meet the expectations of our Customers and respond to the market demand. As a result, VTS offers versatile, reliable and energy-efficient units.

Building of any capacity - from restaurants, through trading centres to huge production plants. Operation in all climatic zones from -40°C to +70°C. All kinds of buildings - residential, commercial, industrial. VENTUS VS10 - VS650 AHUsbring about benefits High performance direct drive PLUG type fans. Light structure - frameless casing of hight class tightness. Three delivery methods available - in packages, in sectionsor as a ready-to-install device. High energy recovery rate - up to 85%. Smooth adjustment of the air flow rateas a STANDARD feature. Optimal selection of the unit size accordingto a building cubature. Reliable control system applications. Energy recovery rate up to 85%! Energy recovery systems ideally suited to any climate conditions. Minimal airstreams exchange in the energy recovery blocks. Sensible and latent heat recovery. VTS Group offer includes: rotary regenerator, cross-flow heat recuperator and run-around coil.

Exceptional rigidity and integrity of the AHU A unique C-shape casing ensures excellent integrity and rigidity of the AHU.Highest possible leak-proof design. highest casing rigidity rating Watch movie Casing classes
friedrich heating and cooling wall units High performancedirect drive PLUG fans
ice buildup on air conditioner condenser Silent operation thanks to innovative airfoil blades with unique trailing edge shape.
air conditioner heater combo window unit home depot Smooth performance regulations using VFD technology. High efficient direct drive - elimination of V-belt transmission. Stable operation, easy controlof VENTUS AHUs Carefully selected and programmed control applications enable professional management of air ventilation and conditioning circuits.

User Interface – for easy AHU status monitoring and management. Fan drives status remote set-up and monitoring. Suited for integration with BMS systems. The structure and operating parameters of VENTUS VS10 - VS650 AHUs meet a number of requirements and standards which is confirmed by international certificates. VTS guarantees excellent product quality and highest level customer service. 2 weeks – delivery of standard AHUs. 24h/7days – VTS Service guarantees the shortest response timeon the market. Up to 5 years of Warantee. User friendly on-line AHU selection tool certified by EUROVENT Select the AHU you need in 60 seconds. Selection parameters are certified by Eurovent. Contact with Technicaland Commercial AdvisorThe requirements on a ventilation system are not always the same. In many applications, all that is required is a straightforward exchange of air, whereas in other applications the requirements can be very exacting with regard to temperature, humidity and purity of the air.

Rosenberg air handling units in the Airbox series have a modular design and can be individually configured. In this way, the appropriate solution can be assembled using a kind of modular principle for each application in a quick and straightforward procedure. Both, in the high-tech area and for classic building technology, air handling units from Rosenberg deliver clean air at the right tempered room climate. Weather-proof and explosion-proof designs are possible, as well as TÜV certified hygiene variants. The units consist of a framework structure with double-skinned panels that have acoustic and thermal insulating properties. The individual modules for the filter, fan, heater, cooler, heat recovery, acoustic insulation as well as the frame materials, are assembled flexibly according to the customers‘ requirements. The F40 series is produced in a frameless design. The panels are screwed together from the outside so that the devices are smooth internal surfaces and are hence hygienically safe.

The air handling units Airbox A20, S40, S60, T60 are equipped with a framework construction made from aluminium or galvanised, rolled steel profiles and aluminium cast corner connectors or plastic corner connectors. In the case of the Airbox A20, the double-skinned panels are insulated with non-combustible, sound and thermal insulating mineral wool. The Airbox S40, S60 and T60 air handling units are also filled with non-combustible, sound and heat insulating rock wool insulation. In addition to galvanised steel panels and the framework construction, it is also possible to select coated steel, aluminium and stainless steel versions in our range. For modules with smaller dimensions, the base frame is manufactured in various heights (100, 300, 500 mm) using galvanised, folded steel sheet. Larger modules have a welded base frame (primed or galvanised). 3 mm aluminium profile 1,5 mm galvanised steelor stainless steel 1,5 mm galvanised steel 1,5 mm aluminiumand thermally decoupled

The main factors which are important for the energy efficiency of an air handling unit are the air velocity in the profile unit face as well as the electric power consumption of the fan which is dependent on the air volume and pressure increase. In a combined air handling unit with heat recovery (HRU), the efficiency and pressure loss of the heat recovery must also be taken into account. We work in accordance with the statutory requirements of the German Energy Saving Ordnance (EnEV), as well as the requirements of the German AHU Manufactures Association (RLT) when selecting the parameters for air velocity, the electrical power consumption of the fans and the efficiency of heat recovery. The criteria of the RLT energy efficiency label correspond to the standard DIN EN 13053 A1 (2011). This standard defines nine air velocity classes from V1 to V9, six heat recovery classes from H1 to H6 as well as six classes for the power consumption of fans from P1 to P6. The specific power consumption of a fan (SFP), installed in the air handling unit, is calculated as defined by the current DIN EN 13779.