amana window ac units

Amana Air Conditioner Puesta En EscenaAire Acondicionado De Ventana For Amana, Goodman and York International-branded units call 800-366-0339 from 8 a.m. to 5 p.m. CT Monday through Friday. For Comfort-Aire and Century-branded units call toll-free at 877-442-4482 from 8 a.m. to 5 p.m. ET Monday through Friday. and click on Recall Info at the bottom right corner of the page for more information. Report an Incident Involving this Product About 5,300 (In addition, about 233,500 PTAC units were recalledin August 2014.) This recall involves Amana, Century, Comfort-Aire, Goodman and York International-branded Packaged Terminal Air Conditioners and Heat Pumps (PTAC), and Amana-branded Room Air Conditioners (RAC). The units are rated 230/208 volt, 3.5 kW and are most often installed through the walls of hotels, motels, apartment buildings and commercial spaces to provide room climate control. The RAC units are installed through the walls or windows of the same types of properties.

The recalled units are beige and have serial numbers ranging from 0701009633 through 0804272329. The brand name is located on the unit's front cover. The serial number is located on the label found by lifting the front cover of PTAC units or the grille of RAC units.
rv ac units colemanAdditionally, any PTAC and RAC units that have a beige power cord labeled with a four-digit date code in the MMYY format and ending in 06 or 07, or ranging from 0108 through 1808 are included in this recall.
hitachi split ac dealers in hyderabad Goodman has received approximately 10 reports of PTACs catching on fire, including four involving property damage.
split ac units montreal to request a free replacement power cord. Non-commercial owners will receive free installation of the power cord and inspection of the PTAC control board for damages.

If the control board has been damaged by the recalled power cord, non-commercial owners will also receive a free installation of a replacement control board. Commercial owners are being contacted directly and will install the power cord and inspect the control board. If the control board has been damaged by the recalled power cord, Goodman will provide a new control board for commercial owners to install. Recalled RAC units do not have a control board. Goodman and heating and cooling equipment dealers nationwide from January 2007 through June 2008 for between $700 and $1,000. Goodman Company, L.P. of Houston, Texas The U.S. Consumer Product Safety Commission is charged with protecting the public from unreasonable risks of injury or death associated with the use of thousands of types of consumer products under the agency’s jurisdiction. Deaths, injuries, and property damage from consumer product incidents cost the nation more than $1 trillion annually. CPSC is committed to protecting consumers and families from products that pose a fire, electrical, chemical or

CPSC's work to help ensure the safety of consumer products - such as toys, cribs, power tools, cigarette lighters and household chemicals -– contributed to a decline in the rate of deaths and injuries associated with consumer products over the past 40 years. Federal law bars any person from selling products subject to a publicly-announced voluntary recall by a manufacturer or a mandatory recall ordered by the To report a dangerous product or a product-related injury go online to www.SaferProducts.gov or call CPSC's Hotline at 800-638-2772 or teletypewriter at 301-595-7054 for the hearing impaired. Consumers can obtain news release and recall information at www.cpsc.gov, on Twitter @USCPSC or by subscribing to CPSC's free e-mail newsletters.Need help finding your Model Number? Why do we need your model number? Every model has its own, specific solutions. If you go to a car mechanic they'll need to know the exact make and model of your car to find the right repair parts.

Appliances are the same. See this guide for help. Amana Air Conditioner Parts Don't let a broken Amana Air Conditioner ruin your day. We offer low prices, award winning service and same day shipping on all Amana Air Conditioner parts to help you repair any of your home appliances. Screw, 8/18 x 3/8 This screw is sold individually. In Stock - Ships Today Screw - 8-18 x 1/2 Screw, 8-18 x 1/2Why Does My A/C Smell Bad?Many homeowners take advantage of window air conditioners to save money on electric bills, cool down areas of their homes that the central air unit doesn’t reach, or make their room cold enough to be able to use a blanket at night. A window air conditioner can be useful for all the reasons listed above, but when dust, water, and heat are combined, they provide the perfect environment for mold and mildew growth if no annual maintenance is performed. Where Did That Mildew Smell Come From?There are several possible reasons for that musty stink:

Window air conditioners have a drip tray that is a necessary component of the system. This collection of water, along with heat and dust, allow for some pretty nasty “muck” to collect over time. The smell associated with this stuff is best described as being sour, moldy, or mildewy. If there's a drainage problem, water may have pooled and mildew may have grown on the filter, condenser coil, or somewhere else inside. If the mold is black (Stachybotrys), it's toxic, and you'll want to get rid of it as quickly and thoroughly as possible. I've outlined some steps below that people take to remove the smell, but it’s always best to refer to any literature that came with the window air conditioner at the time of purchase. WARNING: Most window units are pressurized systems and have a charged capacitor that could cause a shock, so at no time should a homeowner remove anything other than the case, which exposes the internal components of the window air unit. Doing anything other than removing the case may result in personal injury.

Seven Steps to Get Your AC Smelling Right Step One: Remove the Case from the UnitOn smaller window air conditioners, remove the outer metal case of the unit. This should expose the coils, fan, and compressor. In a larger unit, after the front plastic and a few screws are removed, the air conditioner will slide out of the case toward the inside of the room. Be careful not to damage the metal fins on the front and rear of the unit. These are made from aluminum and will bend easily. Step Two: Take It OutsideChoose a location outside where a hose can be used, such as a driveway. Place the window air conditioner on something secure such as a couple of saw horses or a secure table of some kind. The table or saw horses will be exposed to water and bleach, so choose something appropriate for this task. For larger air conditioners, an assistant may be required to lift the unit. Step Three: Remove DustBlow the unit off with compressed air from a distance sufficient to remove dust and debris, but be careful not to damage any components or blow too hard on the aluminum fins.

Wipe off any surface dust or debris with a damp cloth. Step Four: Clean the Fins Using a soft brush such as the type used to remove lint from a dryer vent, stroke the fins up and down to remove debris caked on to the front and rear of the air conditioning unit. Step Five: Clean the Vent and BlowerFill a spray bottle approximately ¼ full of bleach and fill the rest with water. Spray directly into the area where the cool air blows out of the air conditioner. Be sure to get plenty of the solution into the blower fan while turning it slowly. Once the bottle is empty, refill with water and spray in the same area. The goal here is to clean the area with bleach and water, then flush the bleach out with water. Step Six: Flush Tray With WaterUsing a hose, flush all the muck and debris out of the drip tray. Do not spray in the tray. The goal here is to use enough water to flush out the debris, but not to use much pressure. Pressurized water will damage the window air conditioner components.